Magnetic Resonance Imaging
Volume 27, Issue 9 , Pages 1302-1308 , November 2009

An optimized solenoidal head radiofrequency coil for low-field magnetic resonance imaging

  • Barbara Blasiak

      Affiliations

    • Institute of Nuclear Physics, Polish Academy of Sciences, Krakow 31-342, Poland
    • Experimental Imaging Centre, Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada T2N 4N1
    • Institute for Biodiagnostics, National Research Council of Canada, Winnipeg, Manitoba, Canada R3B 1Y6
  • ,
  • Vyacheslav Volotovskyy

      Affiliations

    • Institute for Biodiagnostics, National Research Council of Canada, Winnipeg, Manitoba, Canada R3B 1Y6
  • ,
  • Charlie Deng

      Affiliations

    • Institute for Biodiagnostics, National Research Council of Canada, Winnipeg, Manitoba, Canada R3B 1Y6
  • ,
  • Boguslaw Tomanek

      Affiliations

    • Institute of Nuclear Physics, Polish Academy of Sciences, Krakow 31-342, Poland
    • Experimental Imaging Centre, Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada T2N 4N1
    • Institute for Biodiagnostics, National Research Council of Canada, Winnipeg, Manitoba, Canada R3B 1Y6
    • Corresponding Author InformationCorresponding author. Institute for Biodiagnostics, National Research Council of Canada, Winnipeg, Manitoba, R3B 1Y6, Canada.

Received 25 August 2008 ,Revised 25 January 2009 ,Accepted 7 May 2009.

References 

  1. Yoshika H, Ito S, Handa S, Tomiha S, Kose K, Haishi T, et al. Low-field compact magnetic resonance imaging system for the hand and wrist in rheumatoid arthritis. J Magn Reson Imaging. 2006;23:370–376
  2. Ackerman JJH, Grove TH, Wong GG, Gadian DG, Radda GK. Mapping of metabolites in whole animals by 31P NMR using surface coils. Nature. 1980;283:167–170
  3. Hoult DI, Lauterbur PC. The sensitivity of the zeumatographic experiment involving human samples. J Magn Reson. 1979;34(2):425–433
  4. Chen CN, Hoult DI. Biomedical magnetic resonance technology. New York: IOP Publishing Ltd; 1989;
  5. Abragam A. The principles of nuclear magnetism. Oxford: Oxford Univ Press (Clarendon); 1961;
  6. Edelstein WA, Glover GH, Hardy CJ, Redington RW. The intrinsic signal-to-noise ratio in NMR imaging. Mag Reson Med. 1986;3:604–618
  7. Chen CN, Sank VJ, Cohen SM, Hoult DI. The field dependence of NMR imaging. Laboratory assessment of signal-to-noise ratio and power deposition. Magn Reson Med. 1986;3:722–729
  8. Hoult DI, Sank VJ. The field dependence of NMR imaging. Arguments concerning an optimal field strength. Magn Reson Med. 1986;3:730–746
  9. Taouli B, Zaim S, Peterfy CG, et al. Rheumatoid arthritis of the hand and wrist: comparison of three imaging techniques. AJR Am J Roentgenol. 2004;182:937–943
  10. Savnik A, Malmskov H, Thomsen HS, et al. MRI of the arthritic small joints: comparison of extremity MRI (0.2T) vs high-field MRI (1.5T). Eur Radiol. 2001;11:1030–1038
  11. Marrocco BJD, Drost DJ, Prato FS. An optimized head coil design for MR imaging at 0.15T. Magn Reson Med. 1987;5:143–159
  12. Yousef EL, Alfidi RJ, Duchesneau RH, et al. Initial experience with NMR imaging of the human breast. J Comput Assist Tomogr. 1983;7:215–218
  13. Axel L, Costantinin J, Listerud J. Intensity correction in surface-coil MR imaging. Am J Radiol. 1987;148:418–420
  14. Axel L. Surface coil magnetic resonance imaging. JAMA. 1985;253:828
  15. Hayes CE, Axel L. Noise performance of surface coils for magnetic resonance imaging at 1.5T. Med Phys. 1985;12:604–607
  16. Mirrashed F, Sharp JC, Cheung E, Tomanek B. High-resolution imaging at 3T and 7T with multiring local volume coils. MAGMA. 2004;16:167–173
  17. Haase A, Hanicke W, Frahm J. The influence of experimental parameters in surface coil NMR. J Magn Reson. 1984;56:401–412
  18. Tomanek B, Ryner L, Hoult DI, Kozlowski P, Saunders JK. Dual surface coil with high-B1 homogeneity for deep organ MR imaging. Magn Reson Imaging. 1997;15(10):1199–1204
  19. King SB, Ryner LN, Tomanek B, Sharp J, Smith ICP. MR spectroscopy using multi-ring surface coils. Magn Reson Med. 1999;42:655–664
  20. Crowley MG, Evelhoch JL, Ackerman JJH. The surface-coil NMR receiver in the presence of homogenous B1 excitation. J Magn Reson. 1985;64:20–31
  21. Lufkin RB, Votruba J, Reicher M, Bassett L, Smith DS, Hanafee WN. Solenoid surface coils in magnetic resonance imaging. AJR Am J Roentgenol. 1986;146:409–412
  22. Hoult DI, Richards RE. The signal-to-noise ratio of the magnetic resonance experiment. J Magn Reson. 1976;24:71–85
  23. Hayes CE, Edelstein WA, Schenck JF, Mueller OM, Eash M. An efficient, highly homogenous radiofrequency coil for whole-body NMR imaging at 1.5T. J Magn Reson. 1985;63:622–628
  24. Vullo T, Zipagan R, Pascone RJ, Whalen JP, Cahill PT. Experimental design and fabrication of birdcage resonators for magnetic resonance imaging. Magn Reson Med. 1992;24:243–252
  25. Sank VJ, Chen CN, Hoult DI. A quadrature coil for the adult human head. J Magn Reson. 1986;69:236–242
  26. Vaughan TJ, Hetherington HP, Out JO, Pan JW, Pohost GM. High frequency volume coils for clinical NMR imaging and spectroscopy. Magn Reson Med. 1994;32:206–218
  27. Ginsberg DM, Melchner MJ. Optimum geometry of saddle shaped coils for generating a uniform magnetic field. Rev Sci Instrum. 1970;41:122
  28. Tomanek B, Foniok T, Saunders J, Sutherland G. An integrated RF probe and skull clamp for intraoperative MR imaging. Neurosurgery. 2007;60:179–180
  29. Hoult DI, Tomanek B. Use of mutually inductive coupling in probe design. Concepts in Magnetic Resonance (Magnetic Resonance Engineering) 2002;15(4):262–85.
  30. Lorrain P, Corson DR. Electromagnetic fields and waves: including electric circuits. 2nd ed.. San Francisco: W.H.Freeman and Company; 1988;3 Sub edition
  31. Decorps M, Blondet P, Reutenauer H, Albrand JP, Remy C. An inductively coupled, series-tuned NMR probe. J Magn Reson. 1985;65(1):100–109
  32. Medhurst RG. HF resistance and self-capacitance of single-layer solenoids. Wireless Engineer. 1947;Feb 35–43; Mar 80–92
  33. Gadian DG, Robinson FNH. Radiofrequency losses in NMR experiments on electrically conducting samples. J Magn Reson. 1979;34(2):449–455
  34. Sharp J, Yin D, Tyson R, Lo K, Tomanek B, An Integrated MR. Console/MR physics simulation system. In: Proceedings of ISMRM 14th Annual Scientific Meeting, Seattle. 2006;p. 1351
  35. Li S, Yang QX, Smith MB. RF coil optimization: evaluation of B1 field homogeneity using field histograms and finite element calculations. Mag Reson Imaging. 1994;12(7):1079–1087

PII: S0730-725X(09)00113-1

doi: 10.1016/j.mri.2009.05.018

Magnetic Resonance Imaging
Volume 27, Issue 9 , Pages 1302-1308 , November 2009